Search for a Product

Enter a query in the search input below, and results will be displayed as you type.

Home | Products | Explosive Bridge Wire Testing | 620RK | Mid Range Intrinsically Safe Igniter Tester

620RK | Mid Range Intrinsically Safe Igniter Tester

The AMPTEC 620RK failsafe ohmmeter was specifically designed for ultra-safe testing on squibs, flares, bridge-wire, and other explosive devices. The 620RK meets mid-range resistance requirements, and comes standard with an (OP-232) RS232C interface, and (OP-247) optically isolated power. This product was derived from the USAF Non-Nuclear Munitions Safety Board approved AMPTEC 620A-4 meter – thus creating a product line that is the industry standard in igniter testing.
 

Description

Range 20 Ω 200 Ω 200K Ω
Nominal Current 5 mA .5 mA .5 uA
Failsafe Current 8 mA 1.5 uA 1.5 uA
Resolution 1 mΩ 10 mΩ 10 Ω
Accuracy ± .02% of reading & range ± .02% of reading & range ± .05% of reading & range
Display 4 1/2 digit LED Terminals 4-wire Kelvin
Storage Temperature Range -10° to 70° C Operating Temperature Range 0° to 50° C
Dimensions 9.75″ x 10″ x 3.25″ Weight 3 lbs.
Power 4 ea rechargeable 5AHr NICAD batteries Max. Input Voltage 250 VDC
Open Circuit 1.6 VDC Max. Internal Voltage 4.8 VDC
Update 3 readings/second Temperature Coefficient ± .002% per 1° C

Additional information

Weight 10 lbs
Dimensions 48 × 48 × 48 in
Contact To Purchase
  • Specifications
  • Ordering Information
  • Downloads
Range 20 Ω 200 Ω 200K Ω
Nominal Current 5 mA .5 mA .5 uA
Failsafe Current 8 mA 1.5 uA 1.5 uA
Resolution 1 mΩ 10 mΩ 10 Ω
Accuracy ± .02% of reading & range ± .02% of reading & range ± .05% of reading & range
Display 4 1/2 digit LED Terminals 4-wire Kelvin
Storage Temperature Range -10° to 70° C Operating Temperature Range 0° to 50° C
Dimensions 9.75″ x 10″ x 3.25″ Weight 3 lbs.
Power 4 ea rechargeable 5AHr NICAD batteries Max. Input Voltage 250 VDC
Open Circuit 1.6 VDC Max. Internal Voltage 4.8 VDC
Update 3 readings/second Temperature Coefficient ± .002% per 1° C

Pricing Request

    Downloads

    Data Sheet Manual