Description
Range | 20 Ω | 200 Ω | 2K Ω | 200K Ω |
---|---|---|---|---|
Nominal Current | 5 mA | .5 uA | 50 uA | .05 uA |
Failsafe Current | 8 mA | 1.8 uA | 180 uA | 22 uA |
Resolution | 1 mΩ | 10 mΩ | 100 mΩ | 10 Ω |
Accuracy | ± .02% of reading & range | ± .02% of reading & range | ± .02% of reading & range | ± .02% of reading & range |
Display | 4 1/2 digit LED | Terminal | Trident |
---|---|---|---|
Temperature Coefficient | .1 x Accuracy per 1°C | Operating Temperature Range | 0° to 50° C |
Dimensions | 11.5″ x 13.5″ x 6″ | Weight | 10 lbs. |
Power | 4 ea rechargeable 5AH NICAD batteries | Max Input Voltage | 250 VDC |
Open Circuit | 1.6 VDC | Max Failsafe Current | 8 mA |